st-ten-1/config/machine_settings/st-ten-6.ini

96 lines
2.4 KiB
INI
Raw Normal View History

2023-01-03 16:57:14 +00:00
[machine]
description = ST-TEN-6 DOPPIA PROVA PRESSIONE 6/20 BAR
[hardware_config]
2023-02-17 16:38:03 +00:00
archive_synchronizer: present
2023-04-29 13:11:32 +00:00
uvc_camera: absent
2023-01-03 16:57:14 +00:00
label_printer: present
neo_pixels: present
remote_api: absent
tecna_t3: present
vision_saver: absent
vision: absent
2023-02-14 14:06:31 +00:00
screwdriver: absent
2023-01-03 16:57:14 +00:00
digital_io: present
2023-02-15 12:31:42 +00:00
second_leak_test: present
2023-07-22 10:42:25 +00:00
external_flush_blow: present # EXTERNAL BOX CONTROLLING MULTI-CHANNEL TEST (IF PRESENT), BLOW-CLEANING AND EXTERNAL FLUSH
2023-07-24 16:11:47 +00:00
dual_channel: present
2023-01-03 16:57:14 +00:00
[tecna_t3]
port: COM4
model: t3l
[neo_pixels]
port: COM5
2023-02-26 18:09:46 +00:00
[label_printer]
platform: windows
printer: zd421
[digital_io]
id: USB-5860,BID#0
2023-07-14 15:09:29 +00:00
# OUTPUT MAP
2023-07-24 16:11:47 +00:00
blow_on: 3 # INPUT VALVE TO SERVICE AIR
out_channel_select: 2 # AIR OUT VALVE (0=CH1, 1=CH2)
in_channel_select: 0 # AIR IN VALVE (0=CH1, 1=CH2)
flush_on: 1 # OUTPUT VALVE TO DIRT COLLECTOR
blow_led:7 # CLEAN INDICATOR
ch1_led:6 # CHANNEL 1 ACTIVE INDICATOR
ch2_led:5 # CHANNEL 2 ACTIVE INDICATOR
flush_led:4 # FLUSH INDICATOR
2023-04-29 13:11:32 +00:00
2023-01-03 16:57:14 +00:00
[recipe]
recipe_name_field: codice_ricetta
part_number_field: codice_prodotto
label_template_field: modello_etichetta
description_field: descrizione
2023-02-17 16:38:03 +00:00
[recipes_defaults]
dimensione_lotto_abilitata:
2023-07-14 15:09:29 +00:00
tempo_soffiaggio: 5
2023-02-15 12:31:42 +00:00
tempo_pre_riempimento: 0
pressione_pre_riempimento: 1000
2023-05-20 07:13:03 +00:00
tempo_riempimento: 10
2023-06-10 07:55:19 +00:00
tempo_assestamento: 10
2023-02-21 22:36:27 +00:00
tempo_di_test: 10
2023-02-15 12:31:42 +00:00
percentuale_minima_pressione_assestamento: 5
percentuale_massima_pressione_assestamento: 5
pressione_di_test_delta_minimo: 30
2023-02-16 17:58:01 +00:00
pressione_di_test: 7000
2023-02-15 12:31:42 +00:00
pressione_di_test_delta_massimo: 30
tempo_svuotamento: 1
2023-02-17 10:46:30 +00:00
pressione_svuotamento: 100
2023-07-22 10:42:25 +00:00
canale_di_prova: 1
2023-02-21 22:36:27 +00:00
prova_tenuta_abilitata_2:
2023-02-15 12:31:42 +00:00
tempo_pre_riempimento_2: 0
pressione_pre_riempimento_2: 1000
2023-06-10 07:55:19 +00:00
tempo_riempimento_2: 10
tempo_assestamento_2: 10
2023-02-21 22:36:27 +00:00
tempo_di_test_2: 10
2023-02-15 12:31:42 +00:00
percentuale_minima_pressione_assestamento_2: 5
percentuale_massima_pressione_assestamento_2: 5
2023-02-16 17:58:01 +00:00
pressione_di_test_delta_minimo_2: 30
pressione_di_test_2: 15000
pressione_di_test_delta_massimo_2: 30
2023-02-15 12:31:42 +00:00
tempo_svuotamento_2: 1
2023-02-17 10:46:30 +00:00
pressione_svuotamento_2: 100
2023-07-22 10:42:25 +00:00
canale_di_prova_2: 2
2023-02-21 22:36:27 +00:00
modello_etichetta: EtichettaR5_Montaggio_1prova.prn
2023-01-03 16:57:14 +00:00
2023-02-26 18:09:46 +00:00
[autotest_leak]
enabled: true
pre_filling_time: 0
pre_filling_pressure: 1000
2023-06-10 09:22:26 +00:00
filling_time: 10
2023-02-27 11:17:53 +00:00
settling_time: 10
2023-02-26 18:09:46 +00:00
settling_pressure_min_percent: 5
settling_pressure_max_percent: 5
2023-06-10 09:22:26 +00:00
test_pressure: 7000
2023-05-31 13:02:06 +00:00
test_time: 10
2023-06-10 09:22:26 +00:00
test_pressure_qpos: 5 #Q+ Upper test leak limit
test_pressure_qneg: 15 #Q- Lower test leak limit
test_pressure_tt_qpos: 0 # Q+ Upper test leak limit (tube-tube)
test_pressure_tt_qneg: 5 # Q- Lower test leak limit (tube-tube)
2023-02-26 18:09:46 +00:00
flush_time: 1
flush_pressure: 100
2023-02-27 10:49:51 +00:00
relay_config: 1