From 237c9765437d84d653a1197558e904b4131034cd Mon Sep 17 00:00:00 2001 From: Utente Date: Mon, 7 Oct 2024 12:41:49 +0200 Subject: [PATCH] fix cal --- config/machine_settings/st-ten-4.ini | 14 ++++++-------- 1 file changed, 6 insertions(+), 8 deletions(-) diff --git a/config/machine_settings/st-ten-4.ini b/config/machine_settings/st-ten-4.ini index f088d6f..682b66a 100644 --- a/config/machine_settings/st-ten-4.ini +++ b/config/machine_settings/st-ten-4.ini @@ -13,11 +13,9 @@ vision: absent screwdriver: absent [tecna_t3] -port: COM4 -model: t3p - -[neo_pixels] port: COM5 +model: t3l + [label_printer] platform: windows @@ -59,7 +57,7 @@ tempo_svuotamento_2: 1 pressione_svuotamento_2: 100 canale_di_prova_2: 2 modello_etichetta: EtichettaR5_Montaggio_1prova.prn -pid_pressure_correction: 140 +pid_pressure_correction: 105 [autotest_leak] enabled: true @@ -69,10 +67,10 @@ filling_time: 10 settling_time: 10 settling_pressure_min_percent: 5 settling_pressure_max_percent: 5 -test_pressure: 2000 +test_pressure: 5000 test_time: 10 -test_pressure_qpos: 3 #Q+ Upper test leak limit (negative mbar) -test_pressure_qneg: 15 #Q- Lower test leak limit (negative mbar) +test_pressure_qpos: 8 #Q+ Upper test leak limit (negative mbar) +test_pressure_qneg: 12 #Q- Lower test leak limit (negative mbar) test_pressure_tt_qpos: 1 # Q+ Upper test leak limit (tube-tube) (positive mbar) test_pressure_tt_qneg: 5 # Q- Lower test leak limit (tube-tube) (negative mbar) flush_time: 1