diff --git a/config/machine_settings/st-ten-2semi.ini b/config/machine_settings/st-ten-2semi.ini new file mode 100644 index 0000000..c3513f7 --- /dev/null +++ b/config/machine_settings/st-ten-2semi.ini @@ -0,0 +1,68 @@ +[machine] +description = SEMILAVORATI --- ST-TEN-2 MODALITA' SEMILAVORATI --- COLLAUDO TUBI RISCALDATI VOLPIANO +instruction_folder = st-ten-1 +image_for_warning= generic + +[hardware_config] +archive_synchronizer: present +label_printer: present +multicomp: present +remote_api: absent +tecna_t3: present +leak_disabled: + + +[tecna_t3] +model: t3l +port: COM6 + +[multicomp] +port: COM10 +4wire: enabled + +[recipe] +recipe_name_field: cod semilavorato raccordato e cablato +part_number_field: cod finito cliente +label_template_field: etichetta interoperazionale +barcode_enable_field: verifica_codice_a_barre_abilitata_cl +warning_image_field: immagine_warning + +[recipes_defaults] +descrizione: +prova_tenuta_abilitata: x +verifica_resistenza_connettore_abilitata: x +warning_img:immagine_warning +tempo_pre_riempimento: 0 +pressione_pre_riempimento: 1000 +tempo_riempimento: 10 +tempo_assestamento: 10 +percentuale_minima_pressione_assestamento: 5 +percentuale_massima_pressione_assestamento: 5 +tempo_di_test: 10 +pressione_di_test_delta_minimo: 30 +pressione_di_test: 15000 +pressione_di_test_delta_massimo: 30 +tempo_svuotamento: 1 +pressione_svuotamento: 100 +canale_di_prova: 0 +tester_discharge_enable: yes +n_componenti:1 +pid_pressure_correction: 100 + +[autotest_leak] +enabled: true +pre_filling_time: 0 +pre_filling_pressure: 1000 +filling_time: 10 +settling_time: 10 +settling_pressure_min_percent: 5 +settling_pressure_max_percent: 5 +test_time: 10 +test_pressure_qneg: 50 +test_pressure: 5000 +test_pressure_qpos: 30 +test_pressure_tt_qpos: 1 # Q+ Upper test leak limit (tube-tube) (positive mbar) +test_pressure_tt_qneg: 5 # Q- Lower test leak limit (tube-tube) (negative mbar) +flush_time: 1 +flush_pressure: 100 +relay_config: 1 \ No newline at end of file