diff --git a/config/machine_settings/st-ten-1.ini b/config/machine_settings/st-ten-1.ini index 6d12709..034f829 100644 --- a/config/machine_settings/st-ten-1.ini +++ b/config/machine_settings/st-ten-1.ini @@ -5,7 +5,7 @@ image_for_warning= st-ten-1 [hardware_config] archive_synchronizer: present -# galaxy_camera: present +galaxy_camera: absent uvc_camera: absent label_printer: present neo_pixels: absent @@ -13,7 +13,7 @@ remote_api: absent tecna_t3: present vision_saver: absent vision: absent -screwdriver: present +screwdriver: absent fixture_id: present digital_io: present external_flush_blow: absent diff --git a/config/machine_settings/st-ten-11.ini b/config/machine_settings/st-ten-11.ini index af2e115..543460e 100644 --- a/config/machine_settings/st-ten-11.ini +++ b/config/machine_settings/st-ten-11.ini @@ -14,12 +14,9 @@ vision_saver: absent vision: absent screwdriver: absent digital_io: present -digital_io_flush_blow: present barcode_recipe_selection: present fixture_id: present discard_box: absent -enforce_piece_removal: yes -external_flush_blow: present # EXTERNAL BOX CONTROLLING MULTI-CHANNEL TEST (IF PRESENT), BLOW-CLEANING AND EXTERNAL FLUSH [tecna_t3] port: COM4 @@ -31,18 +28,7 @@ printer: zd421 [digital_io] # OUTPUT MAP FOR FIXTURE CONNECTOR -id_fixture: USB-5862,BID#0 -discard_idx:12 # BIT NUMBER OF THE I/0 MODULE USED FOR DISCARD SENSING - -[digital_io_flush_blow] -id: USB-5860,BID#1 -# OUTPUT MAP FOR EXTERNAL FLUSH/BLOW UNIT -blow_on: 0 # INPUT VALVE TO SERVICE AIR -flush_on: 1 # OUTPUT VALVE TO DIRT COLLECTOR -blow_led:4 # CLEAN INDICATOR -ch1_led:3 # CHANNEL 1 ACTIVE INDICATOR -flush_led:2 # FLUSH INDICATOR - +id: USB-5862,BID#0 [fixture_rfid] port: COM5 @@ -54,7 +40,7 @@ label_template_field: modello_etichetta description_field: descrizione [recipes_defaults] -tester_discharge_enable: no +tester_discharge_enable: yes dimensione_lotto_abilitata: x tempo_pre_riempimento: 0 pressione_pre_riempimento: 1000