From e3ae3531cd8f75307c377e1e3fa4a53d679473f2 Mon Sep 17 00:00:00 2001 From: Utente Date: Thu, 5 Jun 2025 12:59:49 +0200 Subject: [PATCH] stten4 --- config/machine_settings/st-ten-4.ini | 11 ++++++----- 1 file changed, 6 insertions(+), 5 deletions(-) diff --git a/config/machine_settings/st-ten-4.ini b/config/machine_settings/st-ten-4.ini index f352e0e..6bd9b76 100644 --- a/config/machine_settings/st-ten-4.ini +++ b/config/machine_settings/st-ten-4.ini @@ -17,18 +17,18 @@ screwdriver: absent # VERO PROJECT LOCAL SERVER [archive_synchronizer_extra] -portal_address: http://172.20.3.13:45008/ +portal_address: http://172.20.3.13:45011/ poll_time: 10 hold_time: 10 [tecna_t3] port: COM5 -model: t3p +model: t3l [label_printer] platform: windows -printer: zd421 +printer: ZDesigner ZD421-203dpi ZPL [recipe] recipe_name_field: codice_ricetta @@ -67,7 +67,8 @@ tempo_svuotamento_2: 1 pressione_svuotamento_2: 100 canale_di_prova_2: 2 modello_etichetta: EtichettaR5_Montaggio_1prova.prn -pid_pressure_correction: 105 +pid_pressure_correction: 90 +tester_discharge_enable: yes [autotest_leak] enabled: true @@ -79,7 +80,7 @@ settling_pressure_min_percent: 5 settling_pressure_max_percent: 5 test_pressure: 5000 test_time: 10 -test_pressure_qpos: 8 #Q+ Upper test leak limit (negative mbar) +test_pressure_qpos: 7 #Q+ Upper test leak limit (negative mbar) test_pressure_qneg: 12 #Q- Lower test leak limit (negative mbar) test_pressure_tt_qpos: 1 # Q+ Upper test leak limit (tube-tube) (positive mbar) test_pressure_tt_qneg: 5 # Q- Lower test leak limit (tube-tube) (negative mbar)